Skip to main content

Pro+ 13×19 Motorized Wall-Mounted Pergola (Post-to-Post Measurement – Double Bay)

This guide outlines exact measurements and layout for the Pro+ 13×19 (4×6 m) Motorized Wall-Mounted Pergola with center posts (double bay layout).

Updated over 2 weeks ago

📏 Wall-to-Post Measurements – 4 m (13 ft) Wall Side

Measurement Type

Description

mm

in

ft

Wall to Inner Post

Wall surface → inner edge

3705

145.87 in

12.16 ft

Wall to Outer Post

Wall surface → outer edge

3825

150.59 in

12.55 ft

💡 Tip: Measure from the finished wall surface to account for bracket depth.


⚙️ Baseplate-to-Baseplate Measurements – 4 m (13 ft) Wall Side

Measurement Type

Description

mm

in

ft

Wall to Inner Baseplate

Wall → inner edge

3675

144.69 in

12.06 ft

Wall to Outer Baseplate

Wall → outer edge

3855

151.77 in

12.65 ft

💡 Tip: Mark 3855 mm (12.65 ft) for outermost anchor holes.


📏 Post-to-Post Measurements – 6 m (19 ft) Front Side

Measurement Type

Description

mm

in

ft

Outer to Outer Post

Total front length

5688

223.98 in

18.66 ft

Outer to Inner Post

Outer edge → center post edge

2784

109.61 in

9.14 ft

Inner to Inner Post

Center to center open space

2664

104.88 in

8.74 ft

💡 Tip: Center posts divide the 19 ft span into two equal bays ≈ 9.5 ft each.


⚙️ Baseplate-to-Baseplate Measurements – 6 m (19 ft) Front Side

Measurement Type

Description

mm

in

ft

Inner to Inner Baseplate

Between inner edges

2604

102.56 in

8.55 ft

Outer to Inner Baseplate

Outer → center edge

2784

109.61 in

9.14 ft

Outer to Outer Baseplate

Total baseplate span

2964

116.69 in

9.72 ft

💡 Tip: Spacing repeats for front and rear bays.


📐 Post Height Measurements

Measurement Type

Description

mm

in

ft

Post Edge (ground) → Beam

Ground → bottom of beam

2330

91.73 in

7.64 ft

Outer to Outer Post Height

Ground → top of beam

2503

98.54 in

8.21 ft

Post Edge (ground) → Open Louvers Top

Ground → top louvers (open)

2560

100.79 in

8.40 ft

💡 Tip: Maintain ≥ 100 mm (4 in) clearance above louvers for safe motor movement.


🧩 Installation Planning Tips

  1. Level wall beam with laser before anchoring.

  2. Mark 5688 mm × 3945 mm outer corners.

  3. Footers: 400 × 400 mm (16 × 16 in) × 400 mm deep.

  4. Keep 30 mm (1.2 in) tolerance for adjustment.

  5. Seal wall connection with weatherproof sealant.

  6. Check motor side clearance (50 mm / 2 in).

  7. Confirm drainage flow away from wall and center posts.

Did this answer your question?