📏 Wall-to-Post Measurements – 4 m (13 ft) Wall Side
Measurement Type | Description | mm | in | ft |
Wall to Inner Post | From wall surface → inner edge of post | 3705 | 145.87 in | 12.16 ft |
Wall to Outer Post | From wall surface → outer edge of post | 3825 | 150.59 in | 12.55 ft |
💡 Tip: Always measure from the finished wall surface, not siding or trim.
⚙️ Baseplate-to-Baseplate Measurements – 4 m (13 ft) Wall Side
Measurement Type | Description | mm | in | ft |
Wall to Inner Baseplate | Wall → inner baseplate edge | 3675 | 144.69 in | 12.06 ft |
Wall to Outer Baseplate | Wall → outer baseplate edge | 3855 | 151.77 in | 12.65 ft |
💡 Tip: Mark 3855 mm (12.65 ft) for outer anchor positions.
📏 Front Post-to-Post Measurements – 4 m (13 ft) Front Side
Measurement Type | Description | mm | in | ft |
Outer to Outer Post | Full span between front post edges | 3945 | 155.31 in | 12.94 ft |
Outer to Inner Post | Outer → inner edge of opposite post | 3825 | 150.59 in | 12.55 ft |
Inner to Inner Post | Clear opening between post faces | 3705 | 145.87 in | 12.16 ft |
💡 Tip: Keep 3945 mm (12.94 ft) between front outer edges for perfect alignment.
⚙️ Front Baseplate-to-Baseplate Measurements – 4 m (13 ft)
Measurement Type | Description | mm | in | ft |
Inner to Inner Baseplate | Between inner edges | 3645 | 143.50 in | 11.96 ft |
Outer to Inner Baseplate | Outer → inner edge | 3825 | 150.59 in | 12.55 ft |
Outer to Outer Baseplate | Full span across edges | 4005 | 157.68 in | 13.14 ft |
💡 Tip: Use 4005 mm (13.14 ft) when drilling footer anchors.
📐 Post Height Measurements
Measurement Type | Description | mm | in | ft |
Post Edge (ground) → Beam | Ground → bottom of beam | 2330 | 91.73 in | 7.64 ft |
Outer to Outer Post Height | Ground → top of beam | 2503 | 98.54 in | 8.21 ft |
Post Edge (ground) → Open Louvers Top | Ground → top louvers (open) | 2560 | 100.79 in | 8.40 ft |
💡 Tip: Provide ≥ 100 mm (≈ 4 in) overhead clearance for louvers.
🧩 Installation Planning Tips
Align wall beam with laser level before drilling.
Use 3945 mm × 3825 mm for corner layout.
Footers: 400 × 400 mm (16 × 16 in) × 400 mm deep.
Allow 30 mm tolerance for adjustments.
Seal wall beam with weatherproof sealant.
Leave 50 mm (2 in) motor clearance side.
Check drainage flow away from wall.