📏 Wall-to-Post Measurements – 3 m (10 ft) Wall Side
Measurement Type | Description | mm | in | ft |
Wall to Inner Post | From wall to inner post edge | 2664 mm | 104.92 in | 8.74 ft |
Wall to Outer Post | From wall to outer post edge | 2784 mm | 109.61 in | 9.14 ft |
💡 Tip: Confirm that the wall surface is straight and leveled before mounting brackets or beams.
⚙️ Baseplate-to-Baseplate Measurements – 3 m (10 ft) Wall Side
Measurement Type | Description | mm | in | ft |
Wall to Inner Baseplate | From wall to inner baseplate edge | 2634 mm | 103.70 in | 8.64 ft |
Wall to Outer Baseplate | From wall to outer baseplate edge | 2814 mm | 110.83 in | 9.24 ft |
💡 Tip: Use 2814 mm (9.24 ft) to locate outer anchor holes for the posts.
📏 Post-to-Post Measurements – 4 m (13 ft) Front Side
Measurement Type | Description | mm | in | ft |
Outer to Outer Post | Full width between front post edges | 3945 mm | 155.31 in | 12.94 ft |
Outer to Inner Post | Outer → inner edge of opposite post | 3825 mm | 150.59 in | 12.55 ft |
Inner to Inner Post | Clear opening between inner post faces | 3705 mm | 145.87 in | 12.16 ft |
💡 Tip: Use 3945 mm (12.94 ft) for outer post alignment when marking your front beam.
⚙️ Baseplate-to-Baseplate Measurements – 4 m (13 ft) Front Side
Measurement Type | Description | mm | in | ft |
Inner to Inner Baseplate | Inner baseplate spacing | 3645 mm | 143.50 in | 11.96 ft |
Outer to Inner Baseplate | Outer → inner edge | 3825 mm | 150.59 in | 12.55 ft |
Outer to Outer Baseplate | Full baseplate span | 4005 mm | 157.68 in | 13.14 ft |
💡 Tip: The 4005 mm (13.14 ft) spacing ensures perfect frame alignment across both front posts.
📐 Post Height Measurements
Measurement Type | Description | mm | in | ft |
Post Edge (ground) → Beam | Ground to underside of beam | 2350 mm | 92.52 in | 7.71 ft |
Outer to Outer Post Height | Ground to top of beam | 2503 mm | 98.54 in | 8.21 ft |
Post Edge (ground) → Open Louvers Top | Ground to top of louvers (open) | 2560 mm | 100.79 in | 8.40 ft |
💡 Tip: Allow at least 100 mm (≈ 4 in) clearance above louvers for smooth motorized movement.
🧩 Installation Planning Tips
Confirm wall beam alignment using a laser level.
Keep 3945 mm (12.94 ft) between front post outer edges.
Recommended footers: 400 × 400 mm (16 × 16 in), 400 mm deep (16 in).
Maintain 30 mm (1.2 in) of tolerance for adjustments.
Use sealant between wall beam and wall surface.
Allow 50 mm (≈ 2 in) clearance for motor housing.
Check gutter drainage direction before final tightening.