Pro+ 10×10 Motorized Wall-Mounted Pergola (Post-to-Post Measurement)

This article provides the official wall-to-post, baseplate, and height measurements for the Pro+ 10×10 (3×3 m) Motorized Wall-Mounted Pergola. Use these details to plan anchor placement, set concrete footers, and ensure proper wall alignment.

Updated over 2 weeks ago

📏 Wall-to-Post Measurements – 3 m (10 ft) Wall Side

Measurement Type

Description

mm

in

ft

Wall to Inner Post

From wall surface to inner edge of post

2664 mm

104.92 in

8.74 ft

Wall to Outer Post

From wall surface to outer post edge

2784 mm

109.61 in

9.14 ft

💡 Tip: Always measure from the finished wall surface, not from siding or trim, to ensure accurate projection.


⚙️ Baseplate-to-Baseplate Measurements – 3 m (10 ft) Wall Side

Measurement Type

Description

mm

in

ft

Wall to Inner Baseplate

From wall to inner baseplate edge

2634 mm

103.70 in

8.64 ft

Wall to Outer Baseplate

From wall to outer baseplate edge

2814 mm

110.83 in

9.24 ft

💡 Tip: Use 2814 mm (9.24 ft) when marking outer anchor points for footer installation.


📏 Post-to-Post Measurements – 3 m (10 ft) Front Side

Measurement Type

Description

mm

in

ft

Outer to Outer Post

Full span between front posts

2904 mm

114.33 in

9.53 ft

Outer to Inner Post

Outer → inner edge of opposite post

2784 mm

109.61 in

9.14 ft

Inner to Inner Post

Clear open space between inner faces

2664 mm

104.92 in

8.74 ft

💡 Tip: The 2904 mm (9.53 ft) span ensures balanced beam alignment across both front posts.


📐 Post Height Measurements

Measurement Type

Description

mm

in

ft

Post Edge (ground) → Beam

Ground to underside of beam

2350 mm

92.52 in

7.71 ft

Outer to Outer Post Height

Ground to top of beam

2503 mm

98.54 in

8.21 ft

Post Edge (ground) → Open Louvers Top

Max height with louvers open

2560 mm

100.79 in

8.40 ft

💡 Tip: Allow 100 mm (≈ 4 in) clearance above louvers for full opening movement.


🧩 Installation Planning Tips

  1. Confirm wall level and mark the upper wall beam line before drilling.

  2. Use 2904 mm (9.53 ft) between front posts.

  3. Recommended footer size: 400 × 400 mm (16 × 16 in), 400 mm deep (16 in).

  4. Keep 30 mm (1.2 in) tolerance around anchor holes for alignment.

  5. Apply weatherproof sealant between wall beam and surface.

  6. Check motor side clearance (50 mm ≈ 2 in) for wiring access.

  7. Verify water drainage direction away from wall.