📏 Post-to-Post Measurements – 3 m (10 ft) Side

Measurement Type

Description

mm

in

ft

Outer to Outer Post

Distance between the outermost post edges. Defines total pergola width.

2904 mm

114.33 in

9.53 ft

Outer to Inner Post

From the outer edge of one post to the inner edge of the opposite post.

2784 mm

109.61 in

9.13 ft

Inner to Inner Post

Clear open space between both inner post faces (usable width).

2664 mm

104.88 in

8.74 ft

💡 Tip: Use outer-to-outer (2904 mm / 9.53 ft) when marking concrete footings to ensure correct frame alignment.


⚙️ Baseplate-to-Baseplate Measurements – 3 m (10 ft) Side

Measurement Type

Description

mm

in

ft

Inner to Inner Baseplate

Between the inner edges of both baseplates.

2604 mm

102.52 in

8.54 ft

Outer to Inner Baseplate

From outer edge of one baseplate to inner edge of the other.

2784 mm

109.61 in

9.13 ft

Outer to Outer Baseplate

Distance between outermost baseplate edges. Defines full mounting footprint.

2964 mm

116.69 in

9.72 ft

💡 Tip: Anchor bolts should follow the outer-to-outer baseplate spacing (2964 mm / 9.72 ft) for optimal stability.


📏 Post-to-Post Measurements – 4 m (13 ft) Side

Measurement Type

Description

mm

in

ft

Outer to Outer Post

Distance across outermost edges of posts. Defines pergola’s full length.

3945 mm

155.31 in

12.94 ft

Outer to Inner Post

From outer to inner post edge.

3825 mm

150.59 in

12.55 ft

Inner to Inner Post

Clear internal width between posts (usable interior space).

3705 mm

145.87 in

12.16 ft

💡 Tip: Use the outer-to-outer measurement (3945 mm / 12.94 ft) for corner-to-corner alignment when checking squareness.


⚙️ Baseplate-to-Baseplate Measurements – 4 m (13 ft) Side

Measurement Type

Description

mm

in

ft

Inner to Inner Baseplate

Between inner edges of both baseplates.

3645 mm

143.50 in

11.96 ft

Outer to Inner Baseplate

Outer edge → inner edge of opposite baseplate.

3825 mm

150.59 in

12.55 ft

Outer to Outer Baseplate

Full span between outermost edges of baseplates.

4005 mm

157.68 in

13.14 ft

💡 Tip: Confirm 4005 mm (13.14 ft) total width before tightening bolts to ensure all baseplates align evenly.


📐 Post Height Measurements

Measurement Type

Description

mm

in

ft

Post Edge (ground) → Beam

Height from ground to underside of beam.

2330 mm

91.73 in

7.64 ft

Outer to Outer Post Height

Total height from base to top of beam.

2503 mm

98.54 in

8.21 ft

Post Edge (ground) → Open Louvers Top

Maximum height to top of louvers when fully open.

2560 mm

100.79 in

8.40 ft

💡 Tip: Keep at least 100 mm (≈ 4 in) clearance above the pergola for smooth louver movement and proper air ventilation.


⚡ Motor Clearance Recommendation

Allow an additional 50 mm (≈ 2 in) along the motorized beam side for housing and wiring.
Ensure the power outlet is located within 1.5 m (≈ 5 ft) of the control box for a clean and efficient installation.


🧩 Installation Planning Tips

  1. Mark layout using the outer-to-outer post dimensions to position all four corners.

  2. Check diagonals — both should match for a perfectly square structure.

  3. Recommended footer size: 400 × 400 mm (16 × 16 in) × 400 mm (16 in) deep.

  4. Leave 30 mm (1.2 in) adjustment space around footers for minor alignment corrections.

  5. Confirm level baseplates before securing the frame and connecting motor components.

  6. Test motor and louvers before final tightening to verify smooth operation.